Industry leaders since 1992
Fast delivery
Trade counter collection
Experts available 24/7
Read our Trustpilot reviews
MGF Pure Air • MedAir • Compact Oil-Free Air

MGF MedAir Oil-Free Compressors

Compact MGF oil-free compressed-air solutions developed for professional medical, laboratory, veterinary and specialist applications where dependable, filtered air and quiet operation are important.

Oil-Free Compression
Compact 3 Litre Receiver
230V Supply
Quiet Professional Design
Medical & Laboratory Applications

Compact MedAir for Specialist Applications

The product below is the MedAir configuration currently offered through Tanair Compressors. Its compact oil-free design is intended for professional environments where clean, filtered compressed air is required and space or noise may be limited.

MGF's current MedAir family includes aftercooled and membrane-dryer versions for professional medical and laboratory applications. Because the Tanair product shown is an earlier MedAir configuration, confirm the exact connected-equipment pressure, flow, drying and filtration requirements before ordering.

Selection note: do not size a specialist air system from compressor type or headline CFM alone. Final suitability depends on the connected equipment, working pressure, duty cycle, filtration, moisture control, pipework, commissioning and any applicable equipment or regulatory requirements.

Why Choose the MGF MedAir Family?

Oil-Free CompressionCompressor lubricant is not introduced into the compression process, supporting applications where oil carryover from the compressor is undesirable.
Compact FormatCurrent MedAir models use a compact 3 litre stainless-steel receiver arrangement suitable for professional installations where space matters.
Quiet OperationCurrent MedAir 1 and MedAir 2 data quotes approximately 50 dB(A), helping where the compressor is installed near staff, patients or working areas.
Professional ApplicationsMGF positions the current MedAir family for professional medical, laboratory, veterinary and specialist applications requiring clean, filtered oil-free air.
High-Duty Current FamilyCurrent MedAir 1 and MedAir 2 references are specified by MGF for 100% duty operation, subject to correct installation and operating conditions.
Air-Treatment ChoiceCurrent MedAir 1 uses aftercooling and filtration; MedAir 2 adds a membrane dryer for applications needing additional moisture control.

Current MGF MedAir Family Reference

SpecificationMedAir 1MedAir 2Selection Note
Current MGF codeS-OF100-003-MA1S-OF100-003-MA2The Tanair product shown on this page is an earlier MedAir configuration with a different stored SKU.
Air treatmentAftercooler and 5 micron filtrationMembrane dryer and 0.01 micron filtrationChoose treatment from the connected equipment's moisture and filtration requirement.
FAD reference55 L/min / approx. 1.94 CFM @ 3 bar50 L/min / approx. 1.77 CFM @ 3 barCompare airflow at the same working pressure.
Receiver3 litre stainless steel3 litre stainless steelCheck storage volume against demand and operating pattern.
Motor / supply0.7 kW / 220V 50/60Hz0.7 kW / 220V 50/60HzConfirm UK supply and installation protection before order.
NoiseApprox. 50 dB(A)Approx. 50 dB(A)Manufacturer reference for current models.
Duty cycle100%100%Final installation still needs correct ventilation and operating conditions.
Maximum pressure4.5 bar4.5 barConfirm the actual equipment operating pressure.
Dew pointNot a dryer modelApprox. -15°C pressure dew pointUse the connected equipment's stated moisture requirement as the basis for selection.
Important: current MGF public literature now lists MedAir 1 and MedAir 2. The Tanair product card below is an earlier MedAir 3 configuration, so current-family specifications are provided for selection context only and should not be treated as a silent re-specification of that earlier product.

What to Check Before Ordering

Equipment Air DemandConfirm the combined free-air requirement of all connected equipment that may operate at the same time.
Working PressureSize from FAD at the required operating pressure rather than displacement, tank size or maximum compressor pressure.
Moisture RequirementWhere dry air is required, confirm the specified pressure dew point before choosing between aftercooled, membrane-dryer or other treatment options.
Filtration RequirementCheck the connected equipment manufacturer's required filtration and air-quality specification rather than assuming oil-free compression alone is sufficient.
Installation & VentilationAllow for ventilation, service access, electrical protection, condensate management and any installation-specific requirements.
Professional SpecificationFor medical or respiratory equipment, confirm the equipment manufacturer's requirements and any applicable standards before commissioning the complete air system.

MGF MedAir FAQs

What applications is the current MGF MedAir family intended for?

MGF lists professional medical and laboratory uses including pulmonary ventilators, N-CPAP devices, portable/mobile units, veterinary applications and other uses requiring oil-free, clean and filtered compressed air. Final suitability must be checked against the connected equipment.

What is the difference between MedAir 1 and MedAir 2?

Current MedAir 1 uses an aftercooler with 5 micron filtration. Current MedAir 2 adds a membrane dryer with 0.01 micron filtration and a pressure dew point of approximately -15°C.

Is the Tanair MedAir product shown here the same as current MedAir 1 or MedAir 2?

No automatic equivalence should be assumed. The Tanair product uses an earlier MedAir 3 SKU, so we recommend confirming the exact supplied specification before order.

Does oil-free compression automatically make the complete air system suitable for medical use?

No. Oil-free compression is only one part of the system. Final suitability depends on the complete installation, including filtration, drying, pipework, commissioning, maintenance and the connected equipment's requirements.

Can the current MedAir family run continuously?

MGF currently specifies MedAir 1 and MedAir 2 for 100% duty operation, subject to correct installation and operating conditions. The earlier product shown below should be checked against its exact supplied specification.

Can Compressed Air Systems UK help confirm the right configuration?

Yes. Send us the connected equipment make/model, required pressure and flow, expected operating pattern, available electrical supply and any stated filtration or dew-point requirement.

Need Help Specifying an MGF MedAir System?

Tell us what equipment the compressor will supply, the required pressure and flow, operating pattern, available electrical supply and any stated air-quality requirement, and we can help confirm the appropriate configuration.

Industries We Support

Energy, Process & Heavy Industry
Food & Beverage
Automotive & Transport
Manufacturing & Engineering
And many more — talk to us for help sizing the right solution for your application.

Support & Aftercare

WarrantyFull peace of mind guaranteed on all workshop compressors.
UK installation availableProfessional on-site setup by our experienced technicians.
Full Aftermarket SupportComprehensive spares and repairs always ready to go.
UK Based SupportLocal experts just a phone call away for any assistance.
Genuine Service PartsOnly original, high-quality service parts for your machine.
Expert Air AdviceLeverage our 30+ years of technical compressed air knowledge.
Scroll to Top