Semi-Duplex Compressor Packages

Smoke Ventilation Air Compressors

Tanair semi-duplex compressor packages for smoke-ventilation, building-services and other specialist compressed-air installations where the compressor and control arrangement must match the engineered system design.

Tanair Semi-Duplex Compressor Range

Choose from piston and rotary-vane semi-duplex packages with 270-litre or 500-litre air receivers and 230V or 415V supply options. These systems are intended for correctly engineered specialist installations where airflow, receiver capacity, electrical supply and control philosophy have been confirmed for the project.

18–30 CFMStated package air delivery
270L & 500LReceiver options
230V & 415VElectrical supply options
Semi-DuplexTwin-compressor arrangements

Smoke Ventilation Compressor Packages

Compare the packages by air delivery, receiver size, electrical supply and compressor type. For smoke-ventilation or other safety-related systems, selection should follow the project specification, required control sequence and duty/standby strategy.

Compare Semi-Duplex Compressor Packages

ModelAir DeliveryReceiverSupplyCompressor Type
Semi-Duplex Rotary Vane Package30 CFM500 L230V / 415VRotary vane
TAN2BD-270/1SD18 CFM270 L230VPiston
TAN2BD-270/3SD18 CFM270 L415VPiston
TAN3BD-270/1SD30 CFM270 L230VPiston
TAN3BD-270/3SD30 CFM270 L415VPiston
TAN3BD-500/1SD30 CFM500 L230VPiston
TAN3BD-500/3SD30 CFM500 L415VPiston
Safety-system selection: for smoke-ventilation and other safety-related installations, compressor quantity, control logic, operating sequence, receiver sizing, electrical supply and commissioning requirements must follow the project specification and be confirmed by the responsible competent specialist.

How a Semi-Duplex Arrangement Works

A semi-duplex package uses two compressor elements or pumps connected to a shared air receiver. Depending on the system design, suitable controls can alternate the compressors, stage the second unit as demand rises, or provide the operating sequence required by the installation.

Air Demand

Size the package against the required air volume, operating pressure and expected system duty rather than receiver capacity alone.

Electrical Supply

Choose the appropriate 230V or 415V arrangement and confirm starting, isolation and control requirements before installation.

Receiver Capacity

270-litre and 500-litre packages provide different stored-air capacity and installation footprints.

Compressor Type

The range includes piston packages plus a rotary-vane semi-duplex option for suitable specialist applications.

Control Strategy

Alternating, staged or duty/standby operation should be defined by the project design and matched with suitable control equipment.

Service Access

Allow appropriate ventilation, isolation, drainage and clear service access around the compressor package.

Control Panels and System Integration

The compressor package is one part of a smoke-ventilation compressed-air system. Where two compressors need to alternate, stage or provide standby duty, the control arrangement must be selected to suit the project requirements and the electrical supply.

Need a control solution? Tanair also supplies smoke-ventilation control-panel options for compatible twin-compressor installations. Confirm the required voltage, sequence and cause-and-effect requirements before ordering.

Related Smoke Ventilation Equipment

Smoke Ventilation Air Compressor FAQs

What is a semi-duplex air compressor?

A semi-duplex arrangement uses two compressor elements or pumps connected to a shared receiver. The control strategy can alternate or stage them according to the requirements of the installation.

Are 230V and 415V options available?

Yes. The range includes both 230V and 415V packages. Confirm the available electrical supply and the project control requirements before choosing a model.

What receiver sizes are available?

The packages on this page include 270-litre and 500-litre receiver options.

Do I need a dedicated control panel?

Where alternating, staged or duty/standby operation is required, a suitable control arrangement is normally needed. The exact panel, wiring and operating logic must match the system design.

Can Compressed Air Systems UK help with installation and servicing?

Yes. Our team can assist with compressor selection, compressed-air installation and ongoing servicing. For smoke-ventilation and other safety-related systems, the final design, control philosophy and compliance requirements must be confirmed by the responsible competent specialist.

Need Help Specifying a Smoke Ventilation Compressor?

Send us the project airflow, electrical supply, receiver requirement and control philosophy, or speak to our team about the compressor package and associated compressed-air equipment.

Call 0121 753 3330

Industries We Support

Energy, Process & Heavy Industry
Food & Beverage
Automotive & Transport
Manufacturing & Engineering
And many more — talk to us for help sizing the right solution for your application.

Support & Aftercare

WarrantyFull peace of mind guaranteed on all workshop compressors.
UK installation availableProfessional on-site setup by our experienced technicians.
Full Aftermarket SupportComprehensive spares and repairs always ready to go.
UK Based SupportLocal experts just a phone call away for any assistance.
Genuine Service PartsOnly original, high-quality service parts for your machine.
Expert Air AdviceLeverage our 30+ years of technical compressed air knowledge.
Scroll to Top
September Clearance - Limited Stock