Industry leaders since 1992
Fast delivery
Trade counter collection
Experts available 24/7
Read our Trustpilot reviews
7.5 kW Direct-Drive Variable-Speed Screw Compressor

Tanair TAN-S 7.5 VSD: 32 CFM at 10 Bar

A compact direct-drive permanent-magnet VSD screw compressor for correctly sized workshops and light industrial systems where compressed-air demand changes during the working day.

7.5 kW
32 CFM
10 Bar
415V Three Phase
Direct-Drive PM VSD

What the TAN-S 7.5 VSD Is Designed to Do

The Tanair TAN-S 7.5 VSD is a 7.5 kW rotary screw compressor with permanent-magnet variable-speed control. Its current published output is 32 CFM (0.9 m³/min) at up to 10 bar on a 415V, 50 Hz, three-phase supply.

It is aimed at applications where compressed-air demand rises and falls throughout the day. In those conditions, variable-speed control can reduce unnecessary unloaded running compared with a fixed-speed compressor that would otherwise continue operating at full motor speed between changing demand periods.

Size from the application: 7.5 kW and 32 CFM are useful specifications, but suitability depends on your actual peak and average air demand, pressure, duty, operating hours and downstream air-treatment requirements.

Current Technical Specification

SpecificationTAN-S 7.5 VSD
Motor power7.5 kW (10 HP)
Published airflow32 CFM / 0.9 m³/min
Maximum pressure10 bar
Electrical supply415V / 50 Hz / 3 phase
DriveDirect-drive permanent-magnet VSD
CoolingAir cooled
Motor protectionIP55
Published dimensions92 cm × 60 cm × 86 cm
Published weight260 kg
Tanair TAN-S 7.5 VSD 7.5 kW direct-drive variable speed screw air compressor

Where Variable Speed Can Help

Demand Changes Through the Day

The inverter adjusts motor speed as compressed-air demand changes, reducing output when the site needs less air and increasing it again as demand rises.

Less Unloaded Running

On a suitable variable-demand system, this can reduce the time a compressor spends running without producing useful compressed air at full output.

About “up to 35%”: the current product page states potential energy savings up to 35% versus fixed speed. Treat that as a possible result under suitable conditions, not a guaranteed site saving. Real performance depends on load profile, pressure, operating hours, leakage and correct sizing.

Direct Drive: Lower Belt-Related Maintenance

No Drive BeltsThere are no drive belts to inspect, retension or routinely replace.
Simpler TransmissionThe motor connects directly to the compression element rather than through a belt transmission stage.
Still Needs ServicingOil, intake and oil filters, separator elements, coolers, drains and other service items remain part of routine maintenance.

Is 32 CFM Enough for Your Workshop?

That depends on the tools and machines that can run at the same time. A 32 CFM compressor should not automatically be described as suitable for a particular number of workshop bays or users without calculating simultaneous air demand.

Automotive WorkshopsPotentially suitable where the combined demand of tyre, lifting and pneumatic tools remains within the compressor's usable airflow.
FabricationCan suit mixed pneumatic-tool demand where the actual simultaneous CFM has been established.
BodyshopsCompressed-air demand for spraying and sanding must be checked carefully, along with drying and filtration requirements.
CNC SupportMay suit CNC or automated equipment where manufacturer airflow, pressure and air-quality requirements fit the system.
Assembly & PackagingUseful where multiple smaller pneumatic users create a changing demand profile.
Existing Compressor ReplacementCompare the old machine's delivered airflow and operating pattern rather than assuming motor kW alone makes it a like-for-like replacement.

When the 7.5 kW VSD May Not Be the Right Choice

  • Your peak demand regularly exceeds 32 CFM at the required pressure.
  • Your demand is very steady and consistently close to full load.
  • The compressor would be substantially oversized for normal operation.
  • Your site only has 230V single-phase power.
  • Leaks, pressure loss or poor pipework are the main reasons the existing system struggles.

Electrical Supply and Installation

The TAN-S 7.5 VSD requires a 415V, 50 Hz, three-phase supply. The final cable, protection, isolator and installation should be designed from the exact compressor data and the site's electrical conditions by a suitably competent electrician.

  • Confirm the exact electrical data before installation.
  • Provide suitable local isolation and protective devices.
  • Allow adequate service clearance around the cabinet.
  • Provide sufficient ventilation for compressor cooling.
  • Use correctly sized pipework to avoid unnecessary pressure loss.

Air Receiver, Dryer and Filtration

A floor-mounted compressor still needs the rest of the compressed-air system to be considered. The correct receiver, dryer and filters depend on the demand profile and required air quality.

Maintenance Requirements

The direct-drive arrangement reduces belt-related maintenance, but the compressor still needs planned servicing in line with its operating hours and manufacturer requirements.

Compressor Service Items

  • Compressor oil
  • Oil filter
  • Air intake filter
  • Oil separator element
  • Cooler cleaning and inspection

System Service Items

  • Automatic drains
  • Dryer servicing
  • Downstream filter elements
  • Receiver inspection requirements
  • Condensate-treatment equipment

ROI: Avoid Universal Payback Claims

The old article stated that many workshops achieve payback within 12–24 months. That cannot be treated as a general rule. Payback depends on the purchase and installation cost, electricity tariff, annual operating hours, current compressor efficiency and how much demand actually varies.

A meaningful comparison should use real operating data wherever possible.

  • Annual operating hours
  • Peak, average and minimum airflow demand
  • Existing loaded and unloaded hours
  • Current operating pressure
  • Electricity tariff and maintenance cost

Compare the Tanair VSD Range

Related Guides

TAN-S 7.5 VSD FAQs

How much air does the TAN-S 7.5 VSD deliver?

The current published output is 32 CFM (0.9 m³/min) at up to 10 bar.

What electrical supply does it require?

It requires a 415V, 50 Hz, three-phase supply. The final cable, protection and isolation should be selected from the exact machine data and site conditions.

Will it save 35% energy?

Potential savings up to 35% are referenced on the product page, but that should not be treated as guaranteed. Actual savings depend on load profile, pressure, operating hours, system leakage and correct compressor sizing.

Is 32 CFM enough for a multi-bay workshop?

Possibly, but the number of bays is not a sizing method. Add the real airflow requirements of tools and machines that can operate simultaneously and compare that demand with the compressor's usable output.

Is direct drive maintenance-free?

No. Direct drive removes belts and belt tensioning, but oil, filters, separator elements, coolers and other routine service items remain.

Is it suitable for continuous use?

Rotary screw compressors are commonly used in high-duty applications, but suitability should be confirmed against the manufacturer's instructions, site conditions and actual operating profile rather than relying on a blanket continuous-duty claim.

Can I add a dryer and receiver?

Yes. Tanair offers a complete 7.5 kW VSD package, and separate receivers, dryers and filtration can also be selected according to the system requirement.

How much does the TAN-S 7.5 VSD cost?

Use the live product page for current pricing and availability rather than relying on a fixed price inside an advice article.

Is 32 CFM the Right Size for Your Site?

Tell us your current compressor, required pressure, operating hours and which tools or machines run together. We can help assess whether the TAN-S 7.5 VSD is correctly sized and what receiver, dryer and filtration may be needed around it.

Compressed Air Systems UK · Unit 15, Fortnum Close, Birmingham, B33 0LG

Explore More of Our Articles

Scroll to Top